● Special high resolution of ultrasonic near field
● Display of impedance plane and time base scan
● Elliptical sorting field(configuration analysis) can be set in 60.00~99.99%
● Auto/Manual amplitude and phase measurement
● Special unequal phase/amplitude alarm
● Special display mode of multi-impedance plane, time base scan, endoscope, 2D/3D imaging of eddy current array scan.
Magnetic Memory Detecting:
● Channel: 32 (can be extended to 128 channels)
● Minimum measurement distance: 1mm
● Maximum measurement distance: 150mm
● Maximum scanning speed: 0.5m per sec.
Ultrasonic Detecting:
● Frequency range: 0.5~20MHz (three bands for choice)
● Testing range: 0~10000mm (steel longitudinal wave)
● Gain: 0~120dB, step length: 0.5dB
● Linear reject: 0 to 80% full screen
● Rectify: RF, fullwave, half+ and half-
● Vertical linear error: ≤3%
● Sampling precision: 12-bit AD
● Sampling rate: 160MHz
● DAC/TCG curves
● Scan modes: A-SCAN, B-SCAN, C-SCAN
Acoustic Impedance Analysis:
● Frequency range: 64Hz~5MHz
● Real-time display: eight channels with independent frequency
● Elliptical sorting field(configuration analysis) can be set in 60.00~99.99%
Magnetic Flux Leakage:
●Channels: 32 (can be extended to 128 channels)
● Gain: 0~90dB, step length: 0.5 dB
● High-pass filter: 0~500Hz
● Low-pass filter: 10Hz~10KHz
Eddy Current Testing:
● 8 frequency real-time driving
● Frequency range : 64Hz~5MHz
● 32 independent testing channels(can be extended to 128 channels)
● Gain: 0~90dB, step length: 0.5dB
Remote Field Eddy Current Testing:
● Channel: 8
● Frequency range: 5Hz~5KHz
● Gain: 0~90dB
Low Frequency Electromagnetic Detecting:
● Frequency range: 5Hz~5KHz
● Channel: 8